This will take approximately 4 hours minimum. When power is restored, it will come back online and start to recharge the battery (assuming the battery has not totally died). Press Menu button then press 2 and then menu button again. X64 series: Press 7 and hold, press * and then # Note this will only clear the status on the keypad, it will not resolve the low battery issue.Ĩ00 & 805 series: Press 7 and hold for 2 sec and then press #
#Dsc panic button low battery how to#
HOW TO CLEAR “BATTERY LOW” STATUS ON THE KEYPAD OF YOUR SYSTEM It offers you no protection whatsoever.īefore the system switches off completely it will beep several times to warn you, together with a ‘Trouble’ light/ symbol which will be shown on your keypad. If your alarm panel and keypad lose all power during load shedding, your alarm system will not work and nor will your panics. These are general guidelines only and will vary with every system and every battery, but we would advise that you monitor your system based on these guidelines. Wireless Alarm systems 1-32 zones: 6 hours as it uses less power. Between 1-32 zones: if there is no power pack will last 3 hours.

Between 1-16 zones: 3-4 hours on a fully charged battery. Wired Alarm Systems Between 1-8 zones: will generally last between 4-6 hours on a fully charged battery.

If your battery does not last the length of time load shedding exists for or a minimum of one hour, then we recommend you need to change it. Suppliers do not guarantee the life of batteries. The batteries we use are deep discharge batteries and lithium ion which are the best available. This means that the battery does not need to be totally dead for your alarm system and signal transmitting device to shut down.įor this reason, it is very important that you immediately act and replace the battery when you are informed of a “battery low” condition.

It must be noted that alarm systems and signal transmitting devices are designed to shut down when the battery researches a certain voltage (between 10.2-10.7 volts). The battery will deteriorate far more quickly dependent on use. Load shedding is putting a huge strain on the battery, especially when it occurs 2-3 times a day. As a basic guide, a battery takes 4 uninterrupted hours minimum to recharge. If the condition of the battery is not satisfactory, caused by age or continuous power failures for extended periods, the battery will not have sufficient power to allow the alarm system to operate and in addition no signals will be sent to the control center. The purpose of the battery is to provide power to the alarm system in the event of power failures and in addition powers the device responsible for always sending signals to the control center. This has a severe impact on your alarm system and the service that any security company provides.Įvery alarm system has a battery back-up. Load shedding is not a thing of the past, in fact all indications are that the situation will only deteriorate.